Maximal35FE

Power Supply/Charger, Expandable, 1 P/S 12/24VDC @ 6A & 1 P/S 12VDC @ 10A, FAI, LinQ2 Ready, 115VAC, BC800 Enclosure

Maximal35FE Expandable Power System provides system designers and installers with optimum power choices and the highest levels of versatility. It provides 12VDC, 24VDC, or 12VDC and 24VDC simultaneously via two (2) single output power supply/chargers. System includes AC fail, low battery and battery presence monitoring. Enclosure facilitates up to four (4) 12VDC/12AH batteries. All interconnecting equipment must be UL Listed.

  • Input
    • 120VAC 60Hz, 7.0A input.
  • Output
    • 12VDC and/or 24VDC outputs.
      • Maximum output current Options:
        • A) 12VDC @ 6A plus 12VDC @ 10A.
        • B) 24VDC @ 6A plus 12VDC @ 10A.
    • Non power-limited outputs.
    • Aux. power-limited output rated @ 1A (unswitched).
    • Over Voltage Protection.
  • Fuse Ratings
    • Power Supply input fuse rated @ 5A/250V.
  • Fire Alarm Disconnect
    • Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger.
  • Supervision
    • AC fail supervision (form "C" contacts).
    • Notification trigger is selectable for 30 seconds (factory set) or 2 hours.
    • Battery fail & presence supervision (form "C" contacts).
    • Low power shutdown. Prevents deep battery discharge.
  • Battery Charging
    • Capacity: 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure).
    • Type: Sealed lead acid or gel type.
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Visual Indicators
    • Green AC Power LED indicates 120VAC present.
    • AC input and DC output LED indicators.
  • Electrical
      • Temperature:
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
    • Relative Humidity 85% +/- 5%.
      • BTU/Hr (approx.):
        • 12VDC: 98 BTU/Hr.
        • 12VDC & 24VDC: 130 BTU/Hr.
    • System AC input VA requirement: 840VA.
UL Listed For:
Access Control System Units (UL294)
cUL Listed For:
CSA Standard C22.2 No.205-M1983, Signal Equipment
CAN/ULC - s319-05, Electronic Access Control Systems.
 
CSFM - California State Fire Marshal Approved
 
CE Compliant
 
Components of this kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 19"W x 26"H x 6.25"D (483 mm W x 660.4 mm H x 159 mm D).
  • 1/2" and 3/4" combination knockouts.
Weights (approximate):
  • Product Weight: 43.5 Lbs. (19.73 kg).
  • Shipping Weight: 47.5 Lbs. (21.55 kg).