T1RAL33F16

Altronix Access and Power Integration Kit - Trove1AL1R with 2-eFlow6NB, 2-ACMS8

Altronix T1RAL33F16 rack kit is pre-assembled and consists of Trove1AL1R enclosure/backplane with factory installed Altronix power supply/ charger(s) and sub-assemblies.

Specifications

  • Two (2) eFlow6NB Power Supply/Chargers
      • Input
        • Voltage: 120VAC, 60Hz, 7A max.
        • Fusing: 5A / 250V.
      • Output
        • Voltage: Factory set: one (1) eFlow6NB at 12VDC and one (1) at 24VDC.
        • Current: 6A continuous.
        • Maximum Supply Current for Main and Aux. Outputs on eFlow6NB Power Supply boards and ACMS8 Access Power Controller's outputs is 5.3A @ 12VDC and 5.6A @ 24VDC.
        • Auxiliary: Class 2 power-limited @ 1A (unswitched).
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • Two (2) ACMS8 Access Power Controllers
      • Input
        • Voltage: 24VDC from one eFlow6NB and 12VDC from another.
        • Fusing: 15A / 32V.
      • Output
        • Voltage: 12 or 24VDC individually selectable.
        • Eight (8) selectable 12VDC or 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs.
        • b) Form “C” Relays. 28VAC or VDC @ 2.5A Rated.
        • c) Auxiliary power outputs (unswitched).
        • d) Any combination of the above.
        • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
        • Output Fuses: 3A / 32VDC.
      • Indicators (LED's)
        • Voltage: 24VDC from one eFlow6NB and 12VDC from another.
        • Fusing: 15A / 32V.
      • Individual voltage LEDs
        • Green: 12VDC
        • Red/Green: 24VDC
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 156 BTU/Hr.

Agency Listings

 
CE Compliant

Accessories

Name Description
RE2 Rack Mount Battery Enclosure, 2U
WM100 Magnetic Cable Tie Mounts
WM25 Magnetic Cable Tie Mounts
WM5 Magnetic Cable Tie Mounts
Circ1ATSE High Voltage AC Automatic Transfer Switch in Enclosure.

Dimensions & Weight

Enclosure:
  • Trove Rack Mount Enclosure
  • Dimensions 19"W x 3.25"H x 26.5"D (482.6 mm W x 82.6 mm H x 673.1 mm D).
  • Rails extend to 36" (914.4mm). Ample knockouts for convenient use.
Weights (approximate):
  • Product Weigtht: 22 Lbs. (9.98 kg).
  • Shipping Weigtht: 27 Lbs. (12.25 kg).