T2MK3F8DQ

8-Door Altronix/Mercury Access and Power Integration Kit - Trove2M2 with eFlow6NB, LINQ2, ACM8CB, VR6, PDS8CB

Altronix T2MK3F8DQ kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger, Network communication module, 12VDC voltage regulator, eight (8) PTC protected output dual voltage power distribution module and eight (8) PTC protected output access control module. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

Specifications

  • eFlow6NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz.
        • Input Fuse: 5A / 250V.
      • Output
        • Voltage: 24VDC.
        • Current: 6A continuous.
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (2 within enclosure); 40 AH / 65 AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • LINQ2 Network Communication Module
      • Status Monitoring
        • AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection.
        • Input trigger state change; Output (relay and power supply) state change.
      • Programming
        • Battery service date indication.
        • Programmable via USB or web browser.
        • Automated timed events:
        • - Control output relays and power supply via flexible timing parameter.
      • Reporting
        • Programmable dashboard notifications.
        • E-mail notification selectable by event.
        • Event log tracks history (100+ events).
      • Indicators LED
        • Blue LED: Power ON.
  • VR6 Voltage Regulator
      • Input
        • Voltage: 24VDC from eFlow6NB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output: Powered.
  • PDS8CB Dual Input Power Distribution Module
      • Input
        • Voltage: 12VDC from VR6 and 24VDC from eFlow6NB.
        • Input PTC Rating: 9A.
      • Outputs
        • Class 2 power-limited auto-resettable outputs.
        • Voltage: 12VDC and/or 24VDC.
        • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Outputs Ratings
        • PTCs: 2.5A.
      • Indicators (LED)
        • DC Output: Eight (8) individual output LEDs.
        • Green: 12VDC
        • Red: 24VDC.
  • ACM8CB Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow6NB.
        • Main Fuse: 10A / 250V.
      • Outputs
        • Class 2 power-limited auto-resettable outputs.
        • Voltage: 24VDC.
        • Eight (8) 24VDC independently controlled PTC outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Any combination of the above.
        • Output PTCs: 2.5A.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 87 BTU/Hr.

Agency Listings

 
CE Compliant

Accessories

Name Description
LINQ2 Network Communication Module, Control, Monitor and Report Power Supply Diagnostics, Compatible with eFlow Series and MaximalF Power Supply/Chargers
MM12 Mounting Magnets, Twelve (12) Quantity per Pack
MM24 Mounting Magnets, Twenty Four (24) Quantity per Pack
MM4 Mounting Magnets, Four (4) Quantity per Pack
MM8 Mounting Magnets, Eight (8) Quantity per Pack
WM100 Magnetic Cable Tie Mounts
WM25 Magnetic Cable Tie Mounts
WM5 Magnetic Cable Tie Mounts

Dimensions & Weight

Dimensions (approximate):
  • 27.25"W x 21.75"L x 6.5"H (692.15 mm W x 546.1 mm L x 165.1 mm H).
Weights (approximate):
  • Product Weigtht: 40 Lbs. (18.15 kg).