Altronix T2MK7F8PQ kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 24VDC @ 10A power supply/charger, Network communication module, 12VDC voltage regulator, eight (8) fuse protected output dual input/output power distribution module and eight (8) fuse protected output network managed dual input/output power distribution module. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

Specifications

  • eFlow104NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz. 4.5A max.
        • Input Fuse: 6.3A / 250V.
      • Outputs
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • AC Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • LINQ8PD Network Power Distribution Module
      • Input
        • Voltage/Current: Input 1 - 24VDC from PDS8 and Input 2 - 12VDC from PDS8.
      • Outputs
        • Output Ratings: Eight (8) fused outputs rated 3A.
        • Other: Power output(s) can be locally or remotely controlled.
        • Surge suppression.
      • Status Monitoring
        • Power Supply(ies) output voltage and load.
        • Voltage and load of each output.
        • FACP trigger and reset status.
        • Unit temperature (Celsius).
        • Power Supply AC and Battery status.
        • Battery health.
      • Indicators (LED)
        • Bat Local: Charging current status.
        • FACP Triggered / Released.
        • Input Input signal.
        • Out1 - Out8: Output status.
      • Reporting
        • Windows Dashboard Alert messages.
        • E-mail notifications.
        • Event Log tracks history.
      • Programming Features
        • Power Supply(ies) voltage and load limits (High/Low).
        • FACP trigger type (wet or dry-N.O./N.C.).
        • Input Function (FACP reset/tamper).
        • Output Reset Trigger (N.O./N.C.).
        • Battery Monitor Configuration:
        • - Battery condition (Low/Normal/Missing)
        • - Service Date
        • Configurable Output Relay(s).
        • Individual Output Configuration:
        • - Device ID
        • - Voltage and Current Limits (High/Low)
        • - FACP Trigger Setting (latching/non-latching/inactive)
        • - Battery Backup.
      • Fire Alarm Interface
        • Supervised FACP disconnect (Latching or Non-Latching).
        • FACP reset (N.C. or N.O.).
  • VR6 Voltage Regulator
      • Input
        • Voltage: 24VDC from eFlow104NB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output: Powered.
  • PDS8 Power Distribution Module
      • Input
        • Voltage: 12VDC from VR6 and 24VDC from eFlow104NB.
        • Input Fuse: 10A/32V.
      • Outputs
        • Voltage: 12VDC and/or 24VDC.
        • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Outputs Ratings
        • Fuses: 3A/32V.
      • Indicators (LED)
        • DC Output: Eight (8) individual output LEDs.
        • Green: 12VDC
        • Red: 24VDC.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 87 BTU/Hr.

Agency Listings

 
CE Compliant

Accessories

Name Description
MM12 Mounting Magnets, Twelve (12) Quantity per Pack
MM24 Mounting Magnets, Twenty Four (24) Quantity per Pack
MM4 Mounting Magnets, Four (4) Quantity per Pack
MM8 Mounting Magnets, Eight (8) Quantity per Pack
WM100 Magnetic Cable Tie Mounts
WM25 Magnetic Cable Tie Mounts
WM5 Magnetic Cable Tie Mounts

Dimensions & Weight

Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weigtht: 40 Lbs. (18.15 kg).