T2MK3F8Q2

8-Door Altronix/Mercury Access and Power Integration Kit - Trove2M2 with eFlow6NB, LINQ2, ACM8, RSB1

Altronix T2MK3F8Q2 kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger, Network communication module, and eight (8) fuse protected output access control module. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

  • eFlow6NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz.
        • Input Fuse: 5A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Current: 6A continuous.
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity 7AH/12VDC (Up to 2 within enclosure); 40 AH/65 AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • LINQ2 Network Communication Module
      • Status Monitoring
        • AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection.
        • Input trigger state change; Output (relay and power supply) state change.
      • Programming
        • Battery service date indication.
        • Programmable via USB or web browser.
        • Automated timed events: Control output relays and power supply via flexible timing parameter.
      • Reporting
        • Programmable dashboard notifications.
        • E-mail notification selectable by event.
        • Event log tracks history (100+ events).
      • Indicators (LED)
        • Blue LED: Power ON.
  • ACM8 Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow6NB.
        • Input Fuse: 10A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) 24VDC independently controlled fused outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
      • Output Fuses
        • 3.5A/250V.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 87 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 40 Lbs. (18.15 kg).
  • Shipping Weight: 43.75 Lbs. (19.85 kg).
Print

Access controllers not included

*Batteries sold separately