T3CVK77F20

20-Door Altronix/CDVI Access and Power Integration Kit - Trove3CV3 with 2-eFlow104NB, 2-ACM8, ACM4, PD8UL, RSB2 with 2-Rocker Switches

Altronix T3CVK77F20 kit consists of Trove3 enclosure, TCV3 CDVI/Altronix backplane with two (2) 24VDC @ 10A power supply/chargers, two (2) 8-output fused access power controllers, one (1) 4-output fused access power controller and one (1) 8-output fused power distribution module. Also featured is a rocker switch bracket with two (2) rocker switches.
This kit also accommodate various combinations of CDVI Atrium A22K/A22NB/ADH10 boards for up to twenty (20) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

  • Two (2) eFlow104NB Power Supply/Chargers
      • Input
        • Voltage: 120VAC, 60Hz, 4.5A max.
        • Input Fuse: 6.3A / 250V.
      • Output
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Type: Sealed lead acid or gel type.
    • Fuse Rating: 10A @ 32VDC.
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
  • Indicators LED
    • AC Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • Two (2) ACM8 Access Power Controllers
      • Input
        • Voltage: 24VDC from eFlow104NB.
        • Main Fuse: 10A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) independently controlled fused outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
        • Output Fuses: 3.5A / 250V.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • ACM4 Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow104NB.
        • Main Fuse: 10A / 32V.
      • Outputs
        • Voltage: 24VDC.
        • Four (4) independently controlled 2.5A outputs:
        • a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
        • b) Four (4) dry form “C” 5A rated relay outputs.
        • c) Any combination of the above.
        • Four (4) auxiliary power outputs (unswitched).
        • Output Fuses: 3A / 32VDC.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • PDS8UL Power Distribution Module
      • Input
        • Voltage: 24VDC from eFlow104NB.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) fuse protected outputs. 3.5A per output max.
        • Output Fuses: 3.5A / 250V.
      • Indicators (LED)
        • Green LED: DC Output.
  • Environmental
      • Temperature
        • Operating: 0° C to 50° C (32° F to 122° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 263 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 30.12"W x 36.12"H x 7.06"D (768.1 mm W x 917.5 mm H x 179.3 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 54.7 Lbs. (24.8 kg).
  • Shipping Weight: 59.7 Lbs. (27.1 kg).
Print

Access controllers not included

*Batteries sold separately