T2MK3F4DQ

4-Door Altronix/Mercury Access and Power Integration Kit - Trove2M2 with eFlow6NB, LINQ2, ACM4CB, VR6, PDS8CB

Altronix T2MK3F4DQ kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger, Network communication module, 12VDC voltage regulator, eight (8) PTC protected output dual voltage power distribution module and four (4) PTC protected output access control module. This kit also accommodate various combinations of Mercury boards for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

  • eFlow6NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz.
        • Input Fuse: 5A / 250V.
      • Output
        • Voltage: 24VDC.
        • Current: 6A continuous.
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (2 within enclosure); 40 AH / 65 AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • LINQ2 Network Communication Module
      • Status Monitoring
        • AC status; Output current draw; Unit’s temperature; DC output voltage; Low Battery/Battery presence detection.
        • Input trigger state change; Output (relay and power supply) state change.
      • Programming
        • Battery service date indication.
        • Programmable via USB or web browser.
        • Automated timed events:
        • - Control output relays and power supply via flexible timing parameter.
      • Reporting
        • Programmable dashboard notifications.
        • E-mail notification selectable by event.
        • Event log tracks history (100+ events).
      • Indicators LED
        • Blue LED: Power ON.
  • VR6 Voltage Regulator
      • Input
        • Voltage: 24VDC from eFlow6NB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output Powered.
  • PDS8CB Dual Input Power Distribution Module
      • Input
        • Voltage: 12VDC from VR6 and 24VDC from eFlow6NB.
        • Input PTC Rating: 9A.
      • Outputs
        • Class 2 power-limited auto-resettable outputs.
        • Voltage: 12VDC and/or 24VDC.
        • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Outputs Ratings
        • PTCs: 2.5A.
      • Indicators (LED)
        • DC Output: Eight (8) individual output LEDs.
        • Green: 12VDC
        • Red: 24VDC.
  • ACM4CB Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow6NB.
        • Main Fuse: 10A / 32V.
      • Outputs
        • Class 2 power-limited auto-resettable outputs.
        • Voltage: 24VDC.
        • Four (4) independently controlled 2.5A outputs:
        • a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
        • b) Any combination of the above.
        • Four (4) auxiliary power outputs (unswitched).
      • Outputs Ratings
        • PTCs: 2.5A.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 87 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Dimensions (approximate):
  • 27.25"W x 21.75"L x 6.5"H (692.15 mm W x 546.1 mm L x 165.1 mm H).
Weights (approximate):
  • Product Weight: 39.6 Lbs. (18 kg).
  • Shipping Weight: 43.35 Lbs. (19.66 kg).
Print

Access controllers not included