T2SAK7F8

8-Door Altronix/Salto Access and Power Integration Kit - Trove2SA2 with eFlow104NB, ACM8, VR6, PDS8

Altronix T2SAK7F8 kit consists of Trove2 enclosure, TSA2 Salto/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution module.
This kit also accommodates up to four (4) Salto CU42E0, CU4200 or CU4EB8 modules for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

  • eFlow104NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz, 4.5A max.
        • Main Fuse: 6.5A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Current: 10A continuous.
        • Auxiliary: Class 2 power-limited @ 1A (unswitched).
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (2 within enclosure); 40 AH / 65 AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
  • PDS8 Dual Input Power Distribution Module
      • Input
        • Voltage: 24VDC from eFlow104NB and 12VDC from VR6.
        • Main Fuse: 10A / 32V.
      • Outputs
        • Voltage: 12VDC and/or 24VDC.
        • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
        • Output Fuses: 3A / 32VDC.
      • Indicators (LED)
        • DC Output: Eight (8) individual output LEDs.
        • Green: 12VDC
        • Red: 24VDC.
  • VR6 Voltage Regulator
      • Input
        • Voltage: 24VDC from eFlow104NB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output: Powered.
  • ACM8 Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow104NB.
        • Main Fuse: 10A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) independently controlled fused outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
        • Output Fuses: 3.5A / 250V.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 50° C (32° F to 122° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 128 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 54.3 Lbs. (24.6 kg).
  • Shipping Weight: 59.3 Lbs. (26.9 kg).
Print

Access controllers not included

*Batteries sold separately