T3MK75F16ADQ

16-Door Altronix/Mercury Access and Power Integration Kit - Trove3M3 with eFlow102NB, eFlow104NB, (2) LINQ8ACMCB, (2) PDS8CB, RSB2

Altronix T3MK75F16ADQ consists of Trove3 enclosure and TM3 Altronix & Mercury backplane with one 24VDC @ 10A and one 12VDC @ 10A power supply/chargers, two (2) eight (8) PTC protected output managed access control modules and two (2) eight (8) PTC protected output dual input power distribution modules. This kit also accommodates various combinations of Mercury* boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

*Also compatible with these authentic Mercury partners: AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt

  • eFlow104NB Power Supply/Charger - 1
      • Input
        • Voltage: 120VAC, 60Hz, 4.5A.
        • Main Fuse: 6.3A / 250V.
      • Output
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Other: Overvoltage protection. Filtered and regulated.
  • eFlow102NB Power Supply/Charger - 2
      • Input
        • Voltage: 120VAC, 60Hz, 3.5A.
        • Main Fuse: 5A / 250V.
      • Output
        • Voltage: 12VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Other: Overvoltage protection. Filtered and regulated.
  • Both Power Supplies
      • Battery Charging
        • Capacity: 12VDC/12AH (4 within enclosure); 40AH/65AH (requires separate enclosure).
        • Type: Sealed lead acid or gel type.
        • Failover: Upon AC loss, instantaneous.
        • (Batteries are sold separately).
      • Fire Alarm Disconnect
        • Supervised: Latching or non-latching.
        • EOL 10K Resistor.
      • Supervision
        • AC Failure: Form “C” contacts.
        • Battery: Form “C” contacts.
        • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
      • Indicators LED
        • AC Input: 120VAC is present.
        • DC Output: Powered.
        • Battery: Discharged or not connected.
  • Two (2) PDS8CB Dual Input Power Distribution Modules
      • Input
        • Voltage: 24VDC from eFlow102NB and 12VDC from VR6.
        • Input PTC: 9A.
      • Outputs
        • Voltage: 12VDC and/or 24VDC.
        • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Outputs Ratings
        • PTCs: 2.5A.
      • Indicators (LED)
        • DC Output: Eight (8) individual output LEDs.
        • Green: 12VDC
        • Red: 24VDC.
  • Two (2) LINQ8ACMCB Networked Access Power Controllers
      • Input
        • Voltage: 24VDC from eFlow104NB and 12VDC from eFlow102NB
        • Input PTCs: 9A
      • Outputs
        • PTC protected outputs
        • Any of the eight (8) PTC protected power outputs are selectable to follow power Input 1 or Input 2
        • Individual outputs may be set to OFF position for servicing
      • Output PTCs:
        • 2.5A
  • Programming Features:
      • Eight (8) Programmable Outputs:
        • - Fail-safe, fail-secure or auxiliary outputs
        • - Input controlled or manually controlled through software
        • - High (over) and low (under) voltage and current monitoring by output
        • - Multiple outputs may be programmed to be triggered by a single input
        • - Battery back-up by output
      • Eight (8) Programmable Trigger Inputs:
        • - Normally open (NO), Normally closed (NC) or Open collector sink inputs
        • - Wet Input (5VDC - 24VDC) with 10k resistor
        • - Any combination of the above
      • Other Programmable Trigger Inputs:
        • - Monitor power supply(ies) input for voltage and current limits (high/low)
        • - Input and output current calibration, Programmable timer events
        • - Programmable user levels, Enable or disable alerts by type
        • - Programmable alert reporting delay
      • Indicators (LED)
        • Green AC LED: indicates AC trouble condition
        • Green BAT LED: indicates battery trouble condition
        • Green FACP LED: indicates FACP disconnect is triggered
        • Flashing Blue Heartbeat LED: indicates network connection
        • Individual OUT1 - OUT8 Red LEDs: indicate outputs are triggered
        • Individual Voltage LEDs: indicate 12VDC (Green) or 24VDC (Red)
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 217 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 30.12"W x 36.12"H x 7.06"D (768.1 mm W x 917.5 mm H x 179.3 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 85.6 Lbs. (38.83 kg).
  • Shipping Weight: 98.8 Lbs. (44.82 kg).
Print

Access controllers not included

*Batteries sold separately