T2HCK75F16

Up to 16-Door Altronix/Hartmann Controls Access and Power Integration Kit - Trove2HC2 with eFlow104NB, eFlow102NB, (2) ACMS8

News Flash… Altronix lead time for all Trove Access & Power Integration kits are now 15 days max.

Altronix T2HCK75F kit consists of Trove2 enclosure and THC2 Hartmann Controls/Altronix backplane with 12VDC @ 10A and 24VDC @ 10A power supply/chargers and two (2) ACMS8 Access Power Controllers. This kit also accommodates up to two (2) PRS_MASTER and eight (8) PRS_TDM, PRS_IO8 modules for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

  • eFlow104NB Power Supply/Charger - 1:
      • Input
        • Voltage: 120VAC, 60Hz, 4.5A max.
        • Input Fuse: 6.3A / 250V.
      • Output
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • eFlow102NB Power Supply/Charger - 2
      • Input
        • Voltage: 120VAC, 60Hz, 3.5A max.
        • Input Fuse: 5A / 250V.
      • Output
        • Voltage: 12VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Both Power Supplies
      • Battery Charging
        • Type: Sealed lead acid or gel type.
        • Fuse Rating: 15A / 32VDC.
        • Failover: Upon AC loss, instantaneous.
      • Fire Alarm Disconnect
        • Supervised: Latching or non-latching.
        • EOL: 10K Resistor.
      • Supervision
        • AC Failure: Form “C” contacts.
        • Battery: Form “C” contacts.
        • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
      • Indicators (LED)
        • AC Input: 120VAC is present.
        • DC Output: Powered.
        • Battery: Discharged or not connected.
  • ACMS8 Access Power Controller
      • Input
        • Two (2) independent low voltage inputs.
        • Voltage Range: 5VDC to 24VDC, up to 10A each or 20A total input.
        • Current Consumption: 0.6A @ 12V, 0.3A @ 24V with all relays energized.
        • Main Fuse Rating: 15/32A.
      • Trigger Inputs
        • Eight (8) individually controlled trigger inputs:
        • a) Normally open (NO) inputs.
        • b) Normally closed (NC) inputs.
        • c) Open collector sink inputs.
        • d) Wet Input (5VDC - 24VDC) with 10K resistor.
        • e) Any combination of the above.
      • Outputs
        • Fuse protected outputs rated @ 2.5A per output, non power-limited. Total output 20A max.
        • Do not exceed the individual power supply ratings.
        • Eight (8) selectable 5VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs..
        • b) Form “C” Relays. 28VAC or VDC @ 2.5A Rated.
        • c) Auxiliary power outputs (unswitched).
        • d) Any combination of the above.
        • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Output Ratings
        • Fuses are rated 2.5A each.
        • Total output current is determined by the power supply(ies), not to exceed a maximum of 10A for each input.
      • Fire Alarm Disconnect
        • Supervised: Latching or non-latching, individually selectable for any or all of the eight (8) outputs.
        • EOL: 10K Resistor.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Blue LED: FACP disconnect is triggered.
      • Individual voltage LEDs
        • Green: 12VDC
        • Red: 24VDC.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity 85% +/- 5%.
      • BTU/Hr (approx.):
        • 184 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to two (2) 12VDC/7AH Batteries.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 41.3 Lbs. (18.2 kg).
  • Shipping Weight: 45.05 Lbs. (19.9 kg).