T2MK75F16DQV

16-Door Altronix/Mercury Access and Power Integration Kit - Trove2M2 and TMV2 door backplane with eFlow104NBV, LINQ2, (2) ACM8CB, PDS16WCB

Altronix T2MK75F16DQV kit consists of Trove2 enclosure, TM2 Altronix/Mercury backplane and TMV2 door backplane with 24VDC @ 10A and 12VDC @ 10A power supply/chargers, Network communication module, sixteen (16) PTC protected output power distribution module and two eight (8) PTC protected output access control modules. This kit also accommodates various combinations of Mercury* boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

*Also compatible with these authentic Mercury partners: AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

  • eFlow104NBV Power Supply/Charger - 1
      • Input
        • Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A.
        • Main Fuse: 6.5A / 250V.
      • Outputs
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • eFlow102NBV Power Supply/Charger - 2
      • Input
        • Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.1A.
        • Input Fuse: 5A / 250V.
      • Output
        • Voltage: 12VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Both Power Supplies
      • Battery Charging
        • Capacity: 12VDC/12AH (4 within enclosure); 40AH/65AH (requires separate enclosure).
        • Type: Sealed lead acid or gel type.
        • Failover: Upon AC loss, instantaneous.
        • (Batteries are sold separately).
      • Fire Alarm Disconnect
        • Supervised: Latching or non-latching.
        • EOL 10K Resistor.
      • Supervision
        • AC Failure: Form “C” contacts.
        • Battery: Form “C” contacts.
        • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
      • Indicators LED
        • AC Input: 220VAC is present
        • DC Output: Powered
        • Battery: Discharged or not connected
  • LINQ2 Network Communication Module
      • Status Monitoring
        • AC status; Output current draw; Unit’s temperature;
        • DC output voltage; Low Battery/Battery presence detection.
        • Input trigger state change; Output (relay and power supply) state change
      • Programming
        • Battery service date indication
        • Programmable via USB or web browser
        • Automated timed events:
        • - Control output relays and power supply via flexible timing parameter
      • Reporting
        • Programmable dashboard notifications
        • E-mail notification selectable by event
        • Event log tracks history (100+ events)
      • Indicators (LED)
        • Blue LED: Power ON
  • Two (2) ACM8CB Access Power Controllers
      • Input
        • Voltage: 24VDC from eFlow104NBV.
        • Main Fuse: 10A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) 24VDC independently controlled PTC outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
        • Output PTCs: 2.5A.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • PD16WCB Power Distribution Module
      • Input
        • Voltage: 12VDC from eFlow102NBV
      • Outputs
        • Voltage: 12VDC
        • PTCs: 2.5A.
      • Indicators (LED)
        • Green LED: DC Output
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 217 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 50 Lbs. (22.68 kg).
  • Shipping Weight: 53.75 Lbs. (24.38 kg).
Print

Access controllers not included

*Batteries sold separately